sales@ccsignal.com

The modes described below repeat on a 1.2 sec cycle.  Repeated pulses meet SAE max <100ms pulse width unless otherwise noted.

Mode Select Switch

The number of the selected mode can be seen in the switch window

Mode

Day

E

Night

E

0

1 pulse = 330V, 5 pulses = 270V

23.4J

1 pulse = 270V, 5 pulses = 220V

15.6J

1

1 pulse = 330V, 4 pulses = 270V

19.8J

1 pulse = 270V, 4 pulses = 220V

13.2J

2

1 pulse = 330V, 3 pulses = 270V

16.2J

1 pulse = 270V, 3 pulses = 220V

10.8J

3

1 pulse = 330V, 1 pulse = 270V

 9.0J

1 pulse = 270V, 1 pulses = 220V

6.0J

4

5 Pulses = 310V, 150ms

24.0J

5 pulses = 270V, 150ms

18.0J

5

1 pulse = 330V, 5 pulses = 270V

23.4J

1 pulse = 330V, 5 pulses = 270V

24.1J

6

1 pulse = 330V, 4 pulses = 270V

19.8J

1 pulse = 330V, 4 pulses = 270V

20.5J

7

1 pulse = 330V, 3 pulses = 270V

16.2J

1 pulse = 330V, 3 pulses = 270V

16.9J

8

1 pulse = 330V, 1 pulse = 270V

9.0J

1 pulse = 330V, 1 pulse = 270V

9.0J

9

5 Pulses = 310V, 150ms

24.0J

5 Pulses = 310V, 150ms

24.0J

10

Pulse Stream 250V, 150ms

20.6J

Pulse Stream 220V, 150ms

16.0J

11

Pulse Stream 280V, 200ms

19.5J

Pulse Stream 250V, 200ms

15.5J

12

Pulse Stream 330V, 500ms

10.8J

Pulse Stream 280V, 500ms

10.8J

13

No pulses, 13 LED flashes

0.0J

5 Pulses = 310V, 150ms

24.0J

14

5 Pulses = 310V, 150ms

24.0J

No Pulses, 14 LED flashes

0.0J

15

Test Mode, no flashes

 

Test Mode, no flashes